Student Work

DESIGN IMPROVEMENTS FOR THE ACTIVATED SLUDGE WASTEWATER TREATMENT SYSTEM AT THE AMERICAN FARM SCHOOL IN THESSALONIKI, GREECE

Public

Downloadable Content

open in viewer

Due to the decommissioning of the AFS activated sludge WWTS, wastewater was being sent to the municipal WWT plant. Due to more stringent municipal regulations, the WWTS needed to be recommissioned incorporating design improvements. It was determined that irregular influent flowrates and alkaline wastewater sources were major contributors to system inefficiency. To accommodate high flowrate fluctuation, the first aeration and settling tank was evaluated for use as an equalization basin. This would allow flowrate and BOD to be regulated, while improving effluent quality. A pH adjust system was also incorporated into the recommended design. With these improvements, AFS should meet discharge requirements and achieve high quality wastewater effluent on- site for irrigation.

  • This report represents the work of one or more WPI undergraduate students submitted to the faculty as evidence of completion of a degree requirement. WPI routinely publishes these reports on its website without editorial or peer review.
Creator
Publisher
Identifier
  • E-project-032416-152213
Advisor
Year
  • 2016
Sponsor
Date created
  • 2016-03-24
Location
  • Thessaloniki
Resource type
Major
Rights statement
Last modified
  • 2021-01-28

Relations

In Collection:

Items

Items

Permanent link to this page: https://digital.wpi.edu/show/wh246t68b