Fire Performance of a Glass Curtain Wall
ÖffentlichHerunterladbarer Inhalt
open in viewerFor this Major Qualifying Project, a virtual simulation of the fire-resistance test ASTM E2307 for a glass curtain wall system was created using computer software ANSYS. Using the software, knowledge was gained on the thermal and structural performance of these structures during a fire. Information from building codes such as the Uniform Building Code, BOCA National Building Code, the International Building Code and Underwriters Laboratories also allowed for the understanding of the fire-resistance of a curtain wall. Together, the codes and the virtual simulation support in determining whether there is a need for certain per- requisites such as, a 3-foot spandrel inside a curtain wall or having an automatic sprinkler system installed that are reference in the building codes.
- This report represents the work of one or more WPI undergraduate students submitted to the faculty as evidence of completion of a degree requirement. WPI routinely publishes these reports on its website without editorial or peer review.
- Creator
- Publisher
- Identifier
- E-project-042717-154149
- Advisor
- Year
- 2017
- Sponsor
- Date created
- 2017-04-27
- Resource type
- Major
- Rights statement
Beziehungen
- In Collection:
Objekte
Artikel
Miniaturansicht | Titel | Sichtbarkeit | Embargo Release Date | Aktionen |
---|---|---|---|---|
Fire_Performance_of_a_Glass_Curtain_Wall.pdf | Öffentlich | Herunterladen |
Permanent link to this page: https://digital.wpi.edu/show/hq37vq368