Student Work
Heat exchanger design for use in a 5kw SOFC APU
ÖffentlichThis project analyzed compact heat exchangers for use in the National Energy Technology Laboratory's 5kW Solid Oxide Fuel Cell (SOFC) Auxiliary Power Unit (APU). The primary objective was to design small, lightweight heat exchangers that could withstand the harsh environment of the SOFC APU. The impact of material properties and surface configurations on exchanger volume and weight were investigated. Sizing calculations for the Air Preheater centered on plate-type exchangers, while the Steam Generator and Exhaust Condenser were conceptually designed.
- This report represents the work of one or more WPI undergraduate students submitted to the faculty as evidence of completion of a degree requirement. WPI routinely publishes these reports on its website without editorial or peer review.
- Creator
- Publisher
- Identifier
- 02C019M
- Advisor
- Year
- 2002
- Sponsor
- Date created
- 2002-01-01
- Resource type
- Major
- Rights statement